{"product_id":"18-15w-uvc-slim-fixture-for-sterilization","title":"18\" 15W UVC Slim Fixture for Sterilization","description":"\u003ch3 dir=\"auto\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe 18\" Mountable UVC System 120V is a modular ultraviolet system designed for installation in HVAC systems to provide UVC energy for coil and drain pan surface treatment and improved air quality.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003e\u003cstrong\u003eThe system integrates the UVC lamp, fixture housing, power source, and lamp sockets into a single factory-assembled and tested unit. Its modular design allows for flexible installation in both built-up and side-access configurations.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003e\u003cstrong\u003eThe housing is constructed from Type 304 stainless steel and includes male and female power plugs to facilitate fixture-to-fixture connection. The 120V power source uses an electronic, high-frequency rapid-start design with overload protection and RF\/EMI suppression.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003e\u003cstrong\u003eThe UVC lamp is a high-output, hot-cathode T8 lamp with a medium bi-pin base that produces UVGI at 254 nm. The fixture is designed for reliable operation in typical HVAC environments and incorporates safety features to help prevent operation when the fixture is not properly installed.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2 dir=\"auto\"\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCompact 18\" modular design for flexible HVAC installation\u003c\/li\u003e\n\u003cli\u003eSuitable for built-up and side-access configurations\u003c\/li\u003e\n\u003cli\u003eType 304 stainless steel housing\u003c\/li\u003e\n\u003cli\u003eFactory-assembled and tested UVC lamp and fixture\u003c\/li\u003e\n\u003cli\u003e120Vac, 50–60 Hz electrical configuration\u003c\/li\u003e\n\u003cli\u003e0.5A electrical current\u003c\/li\u003e\n\u003cli\u003eHigh-output UVC lamp producing UVGI at 254 nm\u003c\/li\u003e\n\u003cli\u003eElectronic high-frequency rapid-start power source with overload protection\u003c\/li\u003e\n\u003cli\u003eRF and EMI suppression\u003c\/li\u003e\n\u003cli\u003eMedium bi-pin, single-click safety, twist-lock lamp sockets\u003c\/li\u003e\n\u003cli\u003eUVC-resistant polycarbonate sockets\u003c\/li\u003e\n\u003cli\u003eMale and female power plugs for fixture-to-fixture coupling\u003c\/li\u003e\n\u003cli\u003eFixtures can be connected end-to-end for different system configurations\u003c\/li\u003e\n\u003cli\u003eIntegrated safety switch\u003c\/li\u003e\n\u003cli\u003eDesigned for installation in HVAC systems\u003c\/li\u003e\n\u003cli\u003eUL\/C-UL Listed under Category Code ABQK (Accessories, Air Duct Mounted)\u003c\/li\u003e\n\u003cli\u003eUL Standards 153, 1598, and 1995\u003c\/li\u003e\n\u003cli\u003eOne-year warranty on the fixture and lamp\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 dir=\"auto\"\u003eApplications\u003c\/h2\u003e\n\u003cp dir=\"auto\"\u003eThe system is designed for HVAC applications where UVC energy is used to treat surfaces within air-handling equipment. It can be used to help control surface microbes that grow on coils and drain pans, including mold and bacteria.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eThe compact 18\" modular design is particularly suitable for smaller HVAC sections, limited installation spaces, or systems where multiple fixtures are connected together to achieve the required coverage.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eThe modular design allows the fixtures to be installed in either built-up or side-access arrangements and configured for HVAC systems of different sizes.\u003c\/p\u003e\n\u003ch2 dir=\"auto\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv dir=\"auto\" class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable dir=\"auto\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification Details\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Design\u003c\/td\u003e\n\u003ctd\u003eModular\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal System Size\u003c\/td\u003e\n\u003ctd\u003e18\" configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e120Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e50–60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent\u003c\/td\u003e\n\u003ctd\u003e0.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproximate Lamp Length\u003c\/td\u003e\n\u003ctd\u003e16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLamp Type\u003c\/td\u003e\n\u003ctd\u003eHigh-output, hot-cathode T8 UVC lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLamp Diameter\u003c\/td\u003e\n\u003ctd\u003eT8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLamp Base\u003c\/td\u003e\n\u003ctd\u003eMedium bi-pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUVC Output Wavelength\u003c\/td\u003e\n\u003ctd\u003e254 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSocket Type\u003c\/td\u003e\n\u003ctd\u003eMedium bi-pin, single-click safety, twist-lock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSocket Material\u003c\/td\u003e\n\u003ctd\u003eUVC-resistant polycarbonate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Material\u003c\/td\u003e\n\u003ctd\u003eType 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003eElectronic, high-frequency rapid-start\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source Protection\u003c\/td\u003e\n\u003ctd\u003eOverload protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMI\/RF Protection\u003c\/td\u003e\n\u003ctd\u003eRF and EMI suppression\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimension A\u003c\/td\u003e\n\u003ctd\u003e18.19\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimension B\u003c\/td\u003e\n\u003ctd\u003e18.59\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproximate Weight\u003c\/td\u003e\n\u003ctd\u003e3 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e55–135°F (13–57°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference Air Velocity\u003c\/td\u003e\n\u003ctd\u003e500 fpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eHVAC systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eBuilt-up or side access\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection\u003c\/td\u003e\n\u003ctd\u003eMale and female power plugs for fixture-to-fixture coupling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Feature\u003c\/td\u003e\n\u003ctd\u003eIntegrated safety switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eListing\u003c\/td\u003e\n\u003ctd\u003eUL\/C-UL Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUL Category\u003c\/td\u003e\n\u003ctd\u003eABQK – Accessories, Air Duct Mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplicable UL Standards\u003c\/td\u003e\n\u003ctd\u003e153, 1598, and 1995\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 dir=\"auto\"\u003e\u003cbr\u003e\u003c\/h2\u003e\n\u003ch2 dir=\"auto\"\u003eConstruction \u0026amp; Design\u003c\/h2\u003e\n\u003cp dir=\"auto\"\u003eThe UVC lamp and fixture are factory-assembled and tested. The assembly consists of the housing, power source, lamp sockets, and UVC lamp, with components constructed to withstand typical HVAC environments.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eThe stainless steel housing incorporates male and female power plugs at opposite ends, allowing fixtures to be connected together for flexible configurations. Each fixture integrates its components into one assembly to maximize serviceability.\u003c\/p\u003e\n\u003ch2 dir=\"auto\"\u003eSafety\u003c\/h2\u003e\n\u003cp dir=\"auto\"\u003eEach fixture incorporates a safety switch designed to disable operation when the fixture is not properly installed. An access\/viewport door is also available with an eye-protection viewing porthole.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eUV exposure can be hazardous to people and should be controlled through appropriate installation and safety procedures.\u003c\/p\u003e\n\u003ch2 dir=\"auto\"\u003eInstallation\u003c\/h2\u003e\n\u003cp dir=\"auto\"\u003eThe system is designed for installation within HVAC systems and can be configured for either built-up or side-access applications. Fixtures can be connected end-to-end to accommodate different system requirements.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eProfessional installation is recommended to ensure proper positioning, electrical connection, access, and UV safety.\u003c\/p\u003e","brand":"CureUV","offers":[{"title":"Default Title","offer_id":46044835774643,"sku":"198200","price":99.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1343\/9763\/files\/ChatGPTImageSep22_2026_03_29_36PM_7_97be025a-ff0a-4b64-884a-5b9f12fe2b58.png?v=1790105706","url":"https:\/\/www.cureuv.com\/products\/18-15w-uvc-slim-fixture-for-sterilization","provider":"CureUV","version":"1.0","type":"link"}