{"product_id":"opsytec-isr900-industrial-spectroradiometer","title":"Opsytec iSR900 Industrial Spectroradiometer","description":"\u003ch3 data-start=\"277\" data-end=\"694\"\u003eThe iSR900 is an autonomous, high-resolution industrial spectroradiometer engineered for fast and precise measurements across the UV range, visible spectrum, and IR. Its optical system is built around an array spectrometer with no moving parts and a 2048-pixel silicon detector, delivering a spectral resolution of 0.44 nm for stable and repeatable measurements in production environments, labs, and automated setups.\u003c\/h3\u003e\n\u003cp data-start=\"696\" data-end=\"1126\"\u003eFactory-calibrated and traceable to PTB, the iSR900 also offers optional DAkkS testing in an accredited laboratory for applications requiring certified metrology. Its low-scatter optical design ensures high sensitivity in the UV range, supporting accurate irradiance and illuminance evaluation. Control and data processing occur directly inside the device, requiring only a USB or RS485\/RS232 interface for external communication.\u003c\/p\u003e\n\u003cp data-start=\"1128\" data-end=\"1406\"\u003eThe iSR900 is designed to operate with an SMA-905 quartz light guide and compatible radiometric measuring heads for irradiance and illuminance measurements. With both trigger input and output, it integrates seamlessly into automated test stations and industrial process control.\u003c\/p\u003e\n\u003ch3 data-start=\"1413\" data-end=\"1451\"\u003eIncluded \u0026amp; Required Components\u003c\/h3\u003e\n\u003cp data-start=\"1452\" data-end=\"1827\"\u003eThis unit requires an SMA-905 quartz light guide and compatible radiometric measuring heads when measuring irradiance or illuminance. It can be paired with a wide range of optional accessories, including custom extensions for specific applications. Connectivity and control operate through USB, RS485, or RS232 outputs, and all processing is handled internally by the device.\u003c\/p\u003e\n\u003ch3 data-start=\"1834\" data-end=\"1854\"\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"1857\" data-end=\"1888\"\u003eSpectroradiometry (UV–VIS–IR)\u003c\/li\u003e\n\u003cli data-start=\"1891\" data-end=\"1935\"\u003eOnline process control and quality control\u003c\/li\u003e\n\u003cli data-start=\"1938\" data-end=\"1989\"\u003eTesting of light sources including lamps and LEDs\u003c\/li\u003e\n\u003cli data-start=\"1992\" data-end=\"2050\"\u003eInspection of optical materials (e.g., light conductors)\u003c\/li\u003e\n\u003cli data-start=\"2053\" data-end=\"2128\"\u003eQualitative and quantitative analysis in chemistry, pharmacy, and biology\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpectral range\u003c\/td\u003e\n\u003ctd\u003e200–1100 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpectral resolution\u003c\/td\u003e\n\u003ctd\u003e0.44 nm (pixel pitch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpectral bandwidth\u003c\/td\u003e\n\u003ctd\u003e2.3 nm (FWHM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrating\u003c\/td\u003e\n\u003ctd\u003e300 lines\/in (300 l\/mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFocal length\u003c\/td\u003e\n\u003ctd\u003e2.95 in (75 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlaze wavelength\u003c\/td\u003e\n\u003ctd\u003e250 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetector\u003c\/td\u003e\n\u003ctd\u003eSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePixel size\u003c\/td\u003e\n\u003ctd\u003e0.00055 x 0.00787 in (14 x 200 µm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of pixels\u003c\/td\u003e\n\u003ctd\u003e2048\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16 bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegration time\u003c\/td\u003e\n\u003ctd\u003e0.0001 s to 60 s (0.1 ms to 60 s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement duration (typ.)\u003c\/td\u003e\n\u003ctd\u003e0.3 s (300 ms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface\u003c\/td\u003e\n\u003ctd\u003eUSB, RS232, RS485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrigger\u003c\/td\u003e\n\u003ctd\u003eI\/O, rear connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e9.84 x 12.60 x 3.94 in (250 x 320 x 100 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e7.72 lb (3.5 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply voltage\u003c\/td\u003e\n\u003ctd\u003e230 V, 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 25 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e41°F to 104°F (5 to 40 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd\u003e14°F to 140°F (-10 to 60 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;80%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eASCII with CRC-16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eTDS\u003c\/h3\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1343\/9763\/files\/e_spectroradiometer_sr900_82fd67b3-3dde-4847-8bcf-e659a317b7af.pdf?v=1763140131\" target=\"_blank\" rel=\"noopener\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1343\/9763\/files\/e_spectroradiometer_sr900_pages-to-jpg-0001_240x240.jpg?v=1763140101\" alt=\"\" style=\"float: none;\"\u003e\u003c\/a\u003e\u003c\/div\u003e","brand":"Opsytec","offers":[{"title":"Default Title","offer_id":45133475348659,"sku":"512231","price":35998.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1343\/9763\/files\/csm_iSR900-Prozess-Spektrometer-Ansicht2_23dff8672f.jpg?v=1763140028","url":"https:\/\/www.cureuv.com\/products\/opsytec-isr900-industrial-spectroradiometer","provider":"CureUV","version":"1.0","type":"link"}