{"product_id":"opsytec-uv-test-chamber-bs-04","title":"Opsytec UV Test Chamber BS-04","description":"\u003ch3 data-start=\"158\" data-end=\"492\"\u003eThe Opsytec UV Test Chamber BS-04 is a high-performance, industrial-grade system designed for precise UV irradiation of samples under time- or dose-controlled conditions. Built with durability and flexibility in mind, this large chamber is ideal for photo stability testing, UV material evaluation, curing, and biological irradiation.\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"526\" data-end=\"656\"\u003eSpectral configuration: fully configurable for UV-A, UV-B, or UV-C spectral regions, achieving maximum irradiance in each range.\u003c\/li\u003e\n\u003cli data-start=\"659\" data-end=\"780\"\u003eDual lamp control: option for two independently controlled lamp groups, allowing mixed or selective spectral operation.\u003c\/li\u003e\n\u003cli data-start=\"783\" data-end=\"896\"\u003eChamber dimensions: internal area of 86 × 65 cm² and a height of 32 cm, suitable for large or multiple samples.\u003c\/li\u003e\n\u003cli data-start=\"899\" data-end=\"1002\"\u003eSample carrier: sliding tray for easy loading and unloading, supporting up to 20 kg of sample weight.\u003c\/li\u003e\n\u003cli data-start=\"1005\" data-end=\"1133\"\u003eTemperature stability: operating temperature of approximately 77 °F (25 °C), preventing thermal damage to sensitive specimens.\u003c\/li\u003e\n\u003cli data-start=\"1136\" data-end=\"1217\"\u003eIrradiance uniformity: ensures consistent exposure across all sample positions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-start=\"1219\" data-end=\"1239\"\u003eControl systems\u003c\/h4\u003e\n\u003cp data-start=\"1240\" data-end=\"1615\"\u003eThe BS-04 integrates advanced irradiation control through UV-MAT or UV-MAT Touch systems.\u003cbr data-start=\"1329\" data-end=\"1332\"\u003eEach spectral range is regulated separately to maintain a constant dose, compensating for lamp ageing, contamination, or temperature fluctuations.\u003cbr data-start=\"1478\" data-end=\"1481\"\u003eCalibrated sensors with high-accuracy analog-to-digital converters and integrated temperature sensors ensure exact dose measurement.\u003c\/p\u003e\n\u003cp data-start=\"1617\" data-end=\"2034\"\u003eThe UV-MAT Touch is operated via a high-resolution capacitive touchscreen powered by a Cortex ARM processor for fast response and long-term reliability. It is compatible with Windows 10 and 11 for seamless data logging and software control. The interface displays numerical and graphical irradiance data, oscillograms, and parameter settings with intuitive and password-protected configuration directly on the device.\u003c\/p\u003e\n\u003ch4 data-start=\"2036\" data-end=\"2066\"\u003eSoftware and connectivity\u003c\/h4\u003e\n\u003cp data-start=\"2067\" data-end=\"2324\"\u003eOptional PC control enables multi-stage irradiation sequences and comprehensive documentation of all exposure parameters.\u003cbr data-start=\"2188\" data-end=\"2191\"\u003eThe UV-MAT Control Software provides real-time monitoring, graphical data visualization, and export options for detailed reporting.\u003c\/p\u003e\n\u003ch4 data-start=\"2326\" data-end=\"2351\"\u003eTypical applications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli data-start=\"2354\" data-end=\"2405\"\u003ePhoto stability testing of materials and coatings\u003c\/li\u003e\n\u003cli data-start=\"2408\" data-end=\"2470\"\u003eUV and daylight exposure for plastics, paints, and adhesives\u003c\/li\u003e\n\u003cli data-start=\"2473\" data-end=\"2516\"\u003eUV curing, sealing, and bonding processes\u003c\/li\u003e\n\u003cli data-start=\"2519\" data-end=\"2572\"\u003eBiological irradiation (bacteria and cell cultures)\u003c\/li\u003e\n\u003cli data-start=\"2575\" data-end=\"2618\"\u003eControlled UVA-352 \/ UVB-313 irradiations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTechnical specifications\u003c\/h4\u003e\n\u003ctable style=\"width: 100%; height: 293.907px;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.574%; height: 19.5938px;\"\u003eInterior chamber\u003c\/td\u003e\n\u003ctd style=\"width: 66.065%; height: 19.5938px;\"\u003e33.9 × 25.6 × 12.6 in (86 × 65 × 32 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.574%; height: 19.5938px;\"\u003eSliding sample carrier\u003c\/td\u003e\n\u003ctd style=\"width: 66.065%; height: 19.5938px;\"\u003e30.7 × 23.6 in (78 × 60 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.574%; height: 19.5938px;\"\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.065%; height: 19.5938px;\"\u003e37.4 × 28.7 × 27.6 in (95 × 73 × 70 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.574%; height: 19.5938px;\"\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.065%; height: 19.5938px;\"\u003e~132 lb (~60 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.574%; height: 19.5938px;\"\u003ePower consumption    \u003c\/td\u003e\n\u003ctd style=\"width: 66.065%; height: 19.5938px;\"\u003e400 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.574%; height: 19.5938px;\"\u003eLamp lifetime UVA\u003c\/td\u003e\n\u003ctd style=\"width: 66.065%; height: 19.5938px;\"\u003eup to 4,000 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.574%; height: 19.5938px;\"\u003eLamp lifetime UVB\u003c\/td\u003e\n\u003ctd style=\"width: 66.065%; height: 19.5938px;\"\u003eup to 4,000 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.574%; height: 19.5938px;\"\u003eLamp lifetime UVC\u003c\/td\u003e\n\u003ctd style=\"width: 66.065%; height: 19.5938px;\"\u003eup to 9,000 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.574%; height: 19.5938px;\"\u003eNumber of lamps\u003c\/td\u003e\n\u003ctd style=\"width: 66.065%; height: 19.5938px;\"\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.574%; height: 19.5938px;\"\u003eSample temperature\u003c\/td\u003e\n\u003ctd style=\"width: 66.065%; height: 19.5938px;\"\u003e77 °F ± 9 °F (25 °C ± 5 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.574%; height: 19.5938px;\"\u003eSpectra ranges\u003c\/td\u003e\n\u003ctd style=\"width: 66.065%; height: 19.5938px;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.574%; height: 19.5938px;\"\u003eIrradiance UVA\u003c\/td\u003e\n\u003ctd style=\"width: 66.065%; height: 19.5938px;\"\u003e8 mW\/cm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.574%; height: 19.5938px;\"\u003eIrradiance UVA+\u003c\/td\u003e\n\u003ctd style=\"width: 66.065%; height: 19.5938px;\"\u003e10 mW\/cm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.574%; height: 19.5938px;\"\u003eIrradiance UVB\u003c\/td\u003e\n\u003ctd style=\"width: 66.065%; height: 19.5938px;\"\u003e5 mW\/cm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.574%; height: 19.5938px;\"\u003eIrradiance UVC\u003c\/td\u003e\n\u003ctd style=\"width: 66.065%; height: 19.5938px;\"\u003e12 mW\/cm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eTDS\u003c\/h4\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1343\/9763\/files\/e_bs04.pdf?v=1760385316\" target=\"_blank\"\u003e\u003cimg style=\"float: none;\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1343\/9763\/files\/e_bs04_page-0001_240x240.jpg?v=1760385269\"\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003ch4 style=\"text-align: start;\"\u003eSpectral distribution\u003c\/h4\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1343\/9763\/files\/spectra_bs04-bs05_en.pdf?v=1760385409\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1343\/9763\/files\/spectra_bs04-bs05_en_page-0001_240x240.jpg?v=1760385372\" alt=\"\" style=\"float: none;\"\u003e\u003c\/a\u003e\u003c\/div\u003e","brand":"Opsytec","offers":[{"title":"Default Title","offer_id":45059589439667,"sku":"512212","price":23998.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1343\/9763\/files\/uv-testkammer-photostabilitaet_f0d55708-2fc1-406f-911f-2e7b5a539f11.jpg?v=1760386056","url":"https:\/\/www.cureuv.com\/products\/opsytec-uv-test-chamber-bs-04","provider":"CureUV","version":"1.0","type":"link"}